Nutanix SCVMM Fast Clones Plug-in

Hi Everyone…I love to show off the cool Microsoft integrations that Nutanix has and most recently Nutanix released System Center Virtual Machine Manager (SCVMM) 2012 R2 Fast Clones plug-in.

With NOS 4.1.3, Nutanix has released a Fast Clone plugin for SCVMM.  The plug-in has the ability to provide space efficient, low impact clones from SCVMM and quickly. The plugin is a wrapper around Nutanix powershell commands for Fast Cones. The plugin does need proper access rights to the Hyper-V hosts and SCVMM and already should be setup for most environments that have Nutanix with Hyper-V deployed.  You will need to install the plugin on the SCVMM host along with the Nutanix powershell command-lets.

Once you have the SCVMM Fast Clones plug-in installed, you can start creating Fast Clones right away. Installation is quick and easy and creating clones is just as easy as shown below.

To create VM clones using the Nutanix Fast Clones wizard, follow the below steps:

  1. Start the SCVMM
  2. Navigate to the Nutanix hosts.
  3. Select a host and then select the VM to be cloned.
  4. To invoke the wizard, do one of the following: Click the “Nutanix Fast Clone” button on the top menu-bar. Right-click the target VM and select “Nutanix Fast Clone” from the pop-up context menu:
    fastclones2 Fast Clones
  5. In the Introduction screen, read the instructions and then click the “Next” button.  NOTE: On start of the wizard, it makes a connection to the VMM to be able to communicate with it to run SCVMM PowerShell cmdlets to gather information about the selected VM.
    fastclones1 Fast Clones
  6. The “Identity” screen is displayed. The “Source VM Name” and “Source VM Host Name” is prepopulated, enter the following information and then click the “Next” button:
    1. Clone Type: Click the “Clone One Virtual Machine” radio button and enter a name for the clone when creating a single clone or click the “Clone Multiple Virtual Machines” radio button and enter the following information:
      1. VM Prefix Name: This is the root part of the new VM name.
      2. Beginning Suffix: a number to start the numbering of the new VMs
      3. Number of Clones: a number between 1 and 100.
        fastclones3 Fast Clones
  7. In the Authentication screen, enter the Prism and VMM Service Account user names and passwords in the appropriate fields, and then click the “Next” button.
    fastclones4 Fast Clones
  8. In the “Select Path” screen, select the destination path and then click the “Next” button. Leave the default path “as is” or change it to a new path as needed by clicking the “Change the default path” box. Click the Browse button to select a destination path for the clone VMs. This is the path where virtual machine configuration files will be stored. The path must be on the same Nutanix SMB share as the VM configuration file.
    fastclones5 Fast Clones
  9. In the “Add Properties” screen, click the appropriate radio button to either power on or not power on the VMs after cloning and then click the “Next” button.
    fastclones6 Fast Clones
  10. In the Summary screen below, review (confirm) the settings are correct.
    fastclones7 Fast Clones
    Clicking the “View Script” button displays the script to be executed:
    fastclones9 Fast Clones
    Clicking the “Enable Verbose Messages” displays detailed log messages as the VMs are being created.
  11. When the settings are correct, click the “Create” button to create the cloned VM(s). An hour glass is displayed and progress messages are displayed.
  12. After the clones are created, click the Finish button to close the wizard and you just created VM’s at lighting speed.fastclones10 Fast Clones

If you want to check out Fast Clones for your environment, you can download Fast Clones from the Nutanix Portal at https://portal.nutanix.com.

Below is a demo video shows traditional cloning vs Fast Clones that my buddy @mcghem created.  It shows the awesome benefit of Fast Clones.

https://youtu.be/cWGEvjHZxdw

As always, if you have any questions please post a comment.

Until next time….Rob

Nutanix SCOM Management Pack – Monitor Your Nutanix Infrastructure

As a Microsoft Evangelist at Nutanix, I am always asked….”How would you monitor your Nutanix Infrastructure and can I use System Center suite. And my answer always is, “YES, with SCOM”….What is SCOM you ask?
SysCnt-OprtnsMgr_h_rgb_2 Nutanix SCOM Management Pack System Center Operations Manager (SCOM) is designed to be a monitoring tool for the datacenter. Think of a datacenter with multiple vendors representing multiple software and hardware products. Consequently, SCOM was developed to be extensible using the concept of management packs. Vendors typically develop one or more management packs for every product they want plugged into SCOM.

To facilitate these management packs, SCOM supports standard discovery and data collection mechanisms like SNMP, but also affords vendors the flexibility of native API driven data collection.  Nutanix provides management packs that support using the Microsoft System Center Operations Manager (SCOM) to monitor a Nutanix cluster.

Nutanix SCOM Management Pack

The management packs collect information about software (cluster) elements through SNMP and hardware elements through ipmiutil (Intelligent Platform Management Interface Utility) and REST API calls and then package that information for SCOM to digest. Note: The Hardware Elements Management Pack leverages the ipmiutil program to gather information from Nutanix block for Fans, Power Supply and Temperature.
SCOM01 Nutanix SCOM Management Pack

Nutanix provides two management packs:

  • Cluster Management Pack – This management pack collects information about software elements of a cluster including Controller VMs, storage pools, and containers.
  • Hardware Management Pack – This management pack collects information about hardware elements of a cluster including fans, power supplies, disks, and nodes.

Installing and configuring the management packs involves the following simple steps:

  1. Install and configure SCOM on the Windows server system (if not installed) (will blog a post soon on this topic)
  2. Uninstall existing Nutanix management packs (if present)
  3. Open the IPMI-related ports (if not open). IPMI access is required for the hardware management pack
  4. Install the Nutanix management packs
  5. Configure the management packs using the SCOM discovery and template wizards

SCOM02 Nutanix SCOM Management Pack SCOM03 Nutanix SCOM Management Pack SCOM04 Nutanix SCOM Management PackSCOM16 Nutanix SCOM Management PackSCOM17 Nutanix SCOM Management PackSCOM18 Nutanix SCOM Management PackSCOM19 Nutanix SCOM Management PackAfter the management packs have been installed and configured, you can use SCOM to monitor a variety of Nutanix objects including cluster, alert, and performance views as shown in examples below. Also, I check out this great video produced by pal @mcghem . He shows a great demo of the SCOM management pack…Kudo’s Mike….also, check out his blog.

YouTube player

Views and Objects Snapshots SCOM05 Nutanix SCOM Management Pack

Cluster Monitoring SnapshotsSCOM06 Nutanix SCOM Management Pack SCOM07 Nutanix SCOM Management Pack

Cluster Performance Monitoring

SCOM08 Nutanix SCOM Management Pack SCOM09 Nutanix SCOM Management Pack SCOM10 Nutanix SCOM Management Pack SCOM11 Nutanix SCOM Management Pack

Hardware Monitoring Snapshots SCOM12 Nutanix SCOM Management Pack SCOM13 Nutanix SCOM Management Pack

In the following diagram views, users can navigate to the components with failure.

SCOM14 Nutanix SCOM Management Pack

Nutanix Objects Available for Monitoring via SCOM

The following provides an high level overview of Nutanix Cluster with Components:

dsf_overview Nutanix SCOM Management Pack

The following sections describe Nutanix Cluster objects being monitored by this version of MPs:

Cluster

Monitored Element

Description

Version

Current cluster version. This is the nutanix-core package version expected on all the Controller VMs.

Status

Current Status of the cluster. This will usually be  one of started or stopped

TotalStorageCapacity

Total storage capacity of the cluster

UsedStorageCapacity

Number of bytes of storage used on the cluster

Iops

For Performance: Cluster wide average IO operations per second

Latency

For Performance: Cluster wide average latency

CVM Resource Monitoring

Monitored Element

Description

ControllerVMId

Nutanix Controller VM Id

Memory

Total memory assigned to CVM

NumCpus

Total number of CPUs allocated to a CVM

Storage

Storage Pool

A storage pool is a group of physical disks from SSD and/or HDD tier.

Monitored Element

Description

PoolId

Storage pool id

PoolName

Name of the storage pool

TotalCapacity

Total capacity of the storage pool

Note: An alert if there is drop in capacity may indicate a bad disk.

UsedCapacity

Number of bytes used in the storage pool

Performance parameters:

Monitored Element

Description

IOPerSecond

Number of IO operations served per second from this storage pool.

AvgLatencyUsecs

Average IO latency for this storage pool in microseconds

Containers

A container is a subset of available storage within a storage pool. Containers hold the virtual disks (vDisks) used by virtual machines. Selecting a storage pool for a new container defines the physical disks where the vDisks will be stored.

Monitored Element

Description

ContainerId

Container id

ContainerName

Name of the container

TotalCapacity

Total capacity of the container

UsedCapacity

Number of bytes used in the container

Performance parameters:

Monitored Element

Description

IOPerSecond

Number of IO operations served per second from this container.

AvgLatencyUsecs

Average IO latency for this container in  microseconds

Hardware Objects

Cluster

Monitored Element

Description

Discovery IP Address

IP address used for discovery of cluster

Cluster Incarnation ID

Unique ID of cluster

CPU Usage

CPU usage for all the nodes of cluster

Memory Usage

Memory usage for all the nodes of cluster

Node IP address

External IP address of Node

System Temperature

System Temperature

Disk

Monitored Element

Description

Disk State/health

Node state as returned by the PRISM [REST /hosts “state” attribute ]

Disk ID

ID assigned to the disk

Disk Name

Name of the disk (Full path where meta data stored)

Disk Serial Number

Serial number of disk

Hypervisor IP

Host OS IP where disk is installed

Tire Name

Disk Tire

CVM IP

Cluster VM IP which controls the disk

Total Capacity

Total Disk capacity

Used Capacity

Total Disk used

Online

If Disk is online or offline

Location

Disk location

Cluster Name

Disk cluster name

Discovery IP address

IP address through which Disk was discovered

Disk Status

Status of the disk

Node

Monitored Element

Description

Node State/health

Node state as returned by the PRISM [REST /hosts “state” attribute ]

Node IP address

External IP address of Node

IPMI Address

IPMI IP address of Node

Block Model

Hardware model of block

Block Serial Number

Serial number of block

CPU Usage %

 CPU usage for Node

Memory Usage  %

Memory usage for node

Fan Count

Total fans

Power Supply Count

Total Power supply

System Temperature

System Temperature

Fan

Monitored Element

Description

Fan number

Fan number

Fan speed

Fan speed in RPM

Power supply

 Element

Description

Power supply number

Power supply number

Power supply status

Power supply status whether present or absent

If you would like to checkout the Nutanix management pack on your SCOM instance, please go to our portal to download the management pack and documentation.
This management pack was development by our awesome engineering team @ Nutanix. Kudos to Yogi and team for a job well done!!! 😉  I hope I gave you a good feel for Nutanix monitoring using SCOM. As always, if you have any questions or comments, please leave below….

Until next time….Rob

Nutanix Inaugural NEXT 2015 Conference…Miami….A Picture Tour

Image

EXT 2015

A special thanks to @andreleibovici @LauraPadillaSF @jweingarten @Tomorrowisms @LukasLundell @nutanix for all the great pics and videos….
This was our first user conference in sunny Miami, Fla. The conference turned out great and we had lots of customers and partners at the event from around the world. And as you know, its all about the customer. 🙂 Some Highlights include a speech from Condalisa Rice and a guest appearance from Microsoft’s Vjay Tewari from General Manager, Global Network Services. Also, we launch our first NPX boot camp and certified 7 people.

calm .NEXT 2015

said .NEXT 2015
nextkeynotecroud .NEXT 2015
.NEXT 2015
.NEXT 2015

said .NEXT 2015
nextkeynotecroud .NEXT 2015
.NEXT 2015

.NEXT 2015

.NEXT 2015
complex .NEXT 2015
.NEXT 2015

.NEXT 2015 .NEXT 2015
.NEXT 2015
broadsupport .NEXT 2015

YouTube player

nextontour .NEXT 2015
next2016 .NEXT 2015
nextms .NEXT 2015
.NEXT 2015

360view .NEXT 2015
league7 .NEXT 2015Community .NEXT 2015panel .NEXT 2015thankyou .NEXT 2015

.NEXT 2015